Charging System
CHARGING SYSTEM SPECIFICATION CHART
| Items | Specification | |
|---|---|---|
| Alternator | Rate voltage | 13.5 V, 180A |
| Speed in use | 1,000 ~ 18,000 rpm | |
| Voltage regulator | IC regulator built-in type | |
| Regulator setting voltage | 11.7 ~ 12.3 V | |
| Battery | Type | 80 - 35 FL |
| Cold cranking amperage [at -18°C(-0.4°F)] | 780 A | |
| Reserve capacity | 190 min | |
| Specific gravity [at 25°C(77°F)] | 1.280 ± 0.01 | |
NOTE:
- COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
- RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7°C(80.1°F).
Courtesy of HYUNDAI MOTOR CO.