LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 2011 >> Genesis 4.6 >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> General Information (Fuel System (G8BA - GSL 4.6L)) >> Basic Troubleshooting >> Basic Inspection Procedure >> Connector Inspection Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Connector Inspection Procedure

  1. Handling of Connector
    1. Never pull on the wiring harness when disconnecting connectors.
      Fig 1: Precaution - Never Pull On Wiring Harness When Disconnecting Connectors
      G04801490Courtesy of HYUNDAI MOTOR CO.
    2. When removing the connector with a lock, press or pull locking lever.
      Fig 2: Precaution - When Removing Connector With Lock, Press Or Pull Locking Lever
      G04801491Courtesy of HYUNDAI MOTOR CO.
    3. Listen for a click when locking connectors. This sound indicates that they are securely locked.
      Fig 3: Locking Connectors
      G04801492Courtesy of HYUNDAI MOTOR CO.
    4. When a tester is used to check for continuity, or to measure voltage, always insert tester probe from wire harness side.
      Fig 4: Precaution - Measure Voltage, Always Insert Tester Probe From Wire Harness Side
      G04801493Courtesy of HYUNDAI MOTOR CO.
    5. Check waterproof connector terminals from the connector side. Waterproof connectors cannot be accessed from harness side.
      Fig 5: Precaution - Check Waterproof Connector Terminals From Connector Side
      G04801494Courtesy of HYUNDAI MOTOR CO.
      NOTE:
      • Use a fine wire to prevent damage to the terminal.
      • Do not damage the terminal when inserting the tester lead.
  2. Checking Point for Connector
    1. While the connector is connected:

      Hold the connector, check connecting condition and locking efficiency.

    2. When the connector is disconnected:

      Check missed terminal, crimped terminal or broken core wire by slightly pulling the wire harness.

      Visually check for rust, contamination, deformation and bend.

    3. Check terminal tightening condition:

      Insert a spare male terminal into a female terminal, and then check terminal tightening conditions.

    4. Pull lightly on individual wires to ensure that each wire is secured in the terminal.
      Fig 6: Pulling Lightly On Individual Wires
      G04801495Courtesy of HYUNDAI MOTOR CO.
  3. Repair Method of Connector Terminal
    1. Clean the contact points using air gun and/or shop rag.
      NOTE: Never use sand paper when polishing the contact points, otherwise the contact point may be damaged.
    2. In case of abnormal contact pressure, replace the female terminal.