Repair Procedures: Removal
WARNING: This page is about a different variant/trim than selected.
- Remove the coupling assembly. Refer to REMOVAL .
- Remove the extension Cable (A).
- Remove the pressure sensor (A) with 24 mm socket.CAUTION: Keep going horizontal state to prevent leaks during remove the pressure sensor.
Tightening torque: 7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft)