Control Circuit Inspection
■ Check voltage
- IG "OFF". Disconnect HO2S connector.
- IG "ON".
- Measure voltage between Heater Control terminal of the HO2S harness connector and chassis ground.
Specification: 2~3V
- Is voltage within the specification?
YES
- Go to "COMPONENT INSPECTION " procedure.
NO
- Repair as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NOTE: HO2S must have a clean air reference to function properly. The air is obtained by way of the sensor wire(s). Do not attempt to repair the wire(s), connector, or the terminals.