Terminal and Connection Inspection
- Disconnect the Battery terminals and ECM connectors and inspect for looseness, poor connection, bending, corrosion, contamination, deterioration or damage. Reconnect the connectors.
- Connect the GDS and go to "Current Data".
- Monitor Battery sensor values in Current Data, check and wiggle the harness(es), connector(s), and terminal(s).
- Any change in the values indicates a poor connection. Was a connector problem found?
YES
- Repair the connector. go to "Verification Of Repair " procedure.
NO
- Go to "COMPONENT INSPECTION " procedure.