[Feedback Position Sensor]
- Connect the Diagnostic tool to the data link connector.
- Perform the fully open and the fully closing operation of the EEGR valve by using the actuation test.
- Check that the voltage is within the specification
- Specification
| Item | Specification |
|---|---|
| Opened Voltage (V) | 0.75 - 1.25 |
| Closed Voltage (V) | 3.85 - 4.15 |