Manifold Absolute Pressure Sensor (MAPS): Specifications: Specification
| Pressure [kPa (kgf/cm2
, psi)] |
Output Voltage (V) |
| 10 (0.10, 1.45) |
0.5 |
| 20 (0.2, 2.9) |
0.88 |
| 30 (0.3, 4.35) |
1.26 |
| 40 (0.4, 5.8) |
1.64 |
| 50 (0.5, 7.25) |
2.02 |
| 60 (0.61, 8.7) |
2.4 |
| 70 (0.71, 10.15) |
2.79 |
| 80 (0.81, 11.60) |
3.17 |
| 100 (1.01, 14.5) |
3.93 |
| 115 (1.17, 16.67) |
4.5 |