Armature Test
- Check continuity between 2 side-by-side commutator bars. Check each segment the same way. If no continuity exists, replace armature. Check for continuity between each commutator bar and armature shaft. If continuity exists, replace armature.
- If commutator surface is rough, sand lightly using No. 500 or 600 grit sandpaper. Using a micrometer or vernier caliper, measure commutator diameter. If commutator diameter is not within specification, replace armature. See MINIMUM COMMUTATOR DIAMETER table.
- Check depth of insulating mold between commutator bars. If depth is less than .008" (.2 mm), using a hacksaw blade or file, undercut to .020-.031" (.5-.8 mm).
MINIMUM COMMUTATOR DIAMETER
| Application | In. (mm) |
|---|---|
| Q45 | 1.134 (28.8) |