September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Operation Procedure
- Touch "DATA MONITOR" on "SELECT DIAG MODE" screen.
- Touch either "ALL SIGNALS" or "SELECTION FROM MENU" on the "DATA MONITOR" screen.
DIAGNOSIS PROCEDURE
| ALL SIGNALS |
Monitors all signals. |
| SELECTION FROM MENU |
Selects and monitors individual signal. |
- When "SELECTION FROM MENU" is selected, touch individual items to be monitored. When "ALL SIGNALS" is selected, all items will be monitored.
- Touch "START".
- Touch "RECORD" while monitoring, then the status of the monitored item can be recorded. To stop recording, touch "STOP".