Communication System B
- CONNECTOR INSPECTION
Check the terminals (at the control unit and harness) on the malfunctioning LCU for disconnection, bend, and other malfunctions.
OK or NG
- OK: GO TO 2.
- NG: Repair terminals and connections.
- LCU INSPECTION
Replace the LCU with a known-good one, and perform the communication diagnosis.
Refer to IVMS COMMUNICATION INSPECTION (with CONSULT-II) or COMMUNICATION DIAGNOSIS (without CONSULT-II).
OK or NG
- OK: Replace LCU.
- NG: Repair communication harness between the indicated LCU and BCM.