3. Check Harness Continuity
- Disconnect BCM connector.
- Check continuity between BCM connector M4 terminal 109 (LG) and trunk lid opener cancel switch connector M117 terminal 2 (LG).
- 109 (LG) - 2 (LG) : Continuity should exist .
- Check continuity between trunk lid opener cancel switch connector M117 terminal 2 (LG) and ground.
- 2 (LG) - Ground : Continuity should not exist .
OK or NG
- OK: Trunk lid opener cancel switch circuit is OK.
- NG: Repair or replace harness.