Diagnostic Procedure
- CHECK STEERING LOCK UNIT POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect steering lock unit connector.
- Check voltage between steering lock unit connector and ground.TERMINAL VOLTAGE CHART
Terminals Voltage (V) (Approx.) (+) (-) Steering lock unit connector Terminal M35 7 Ground Battery voltage
OK or NG
OK: GO TO 3.
NG: GO TO 2.
- CHECK HARNESS CONTINUITY 1
- Disconnect Intelligent Key unit connector.
- Check continuity between Intelligent Key unit connector and steering lock unit connector.TERMINAL CONTINUITY CHART
A B Continuity Intelligent Key unit connector Terminal Steering lock unit connector Terminal M32 15 M35 7 Yes - Check continuity between Intelligent Key unit connector and ground.TERMINAL CONTINUITY CHART
A Ground Continuity Intelligent Key unit connector Terminal M32 15 No
OK or NG
OK: Check the condition of harness and connector.
NG: Repair or replace harness.
- CHECK STEERING LOCK UNIT SIGNAL
- Connect steering lock unit connector.
- Check voltage between steering lock unit connector and ground.TERMINAL VOLTAGE CHART
Terminals Condition Voltage (V) (Approx.) (+) (-) Steering lock unit connector Terminal M35 4 Ground When turn ignition switch to START with Intelligent Key in the car Battery voltage
↓
0
↓
Battery voltage
OK or NG
OK: Replace steering lock unit.
NG: GO TO 4.
- CHECK HARNESS CONTINUITY 2
- Turn ignition switch OFF.
- Disconnect Intelligent Key unit and steering lock unit connector.
- Check continuity between Intelligent Key unit connector and steering lock unit connector.TERMINAL CONTINUITY CHART
A B Continuity Intelligent Key unit connector Terminal Steering lock unit connector Terminal M32 16 M35 4 Yes - Check continuity between Intelligent Key unit connector and ground.TERMINAL CONTINUITY CHART
A Ground Continuity Intelligent Key unit connector Terminal M32 16 No
OK or NG
OK: Check the condition of harness and connector. If it is OK, check the self-diagnosis results using CONSULT-II again.
NG: Repair or replace harness.