Component Function Check
- CHECK FUNCTION
- Select "MEMORY SW 1", "MEMORY SW 2" in "Data Monitor" mode with CONSULT-III.
- Check seat memory switch signal under the following conditions.MONITOR ITEM STATUS REFERENCE
Monitor item Condition Status MEMORY SW 1 Memory switch 1 Press ON Release OFF MEMORY SW 2 Memory switch 2 Press ON Release OFF
Is the indication normal?
YES: INSPECTION END
NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".