Component Function Check
- CHECK FUNCTION
- Turn ignition switch ON.
- Select "RECLN SW-FR", "RECLN SW-RR" in "Data monitor" mode with CONSULT-III.
- Check reclining switch signal under the following conditions.
DATA MONITOR REFERENCE
| Monitor item | Condition | Status | |
|---|---|---|---|
| RECLINE SW-FR | Reclining switch (forward) | Operate | ON |
| Release | OFF | ||
| RECLINE SW-RR | Reclining switch (backward) | Operate | ON |
| Release | OFF | ||
Is the indication normal?
YES: INSPECTION END
NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".