Output Test
- Set variable resistor to minimum resistance position. See Figure. Close switches "SW1" and "SW2".
- Keep voltage constant while raising alternator speed by adjusting variable resistor. Measure alternator output current at 2500 and 5000 alternator RPM. See ALTERNATOR AMPERAGE OUTPUT SPECIFICATIONS table.
ALTERNATOR AMPERAGE OUTPUT SPECIFICATIONS
| Alternator |
Output @ 2500 RPM |
Output @ 5000 RPM |
| LR150-78 |
40 |
50 |
| LR150-98B |
40 |
50 |
| LR150-99 |
40 |
50 |
| LR150-125B |
42 |
50 |
| LR155-15 |
50 |
55 |
| LR160-78 |
50 |
60 |
| LR160-82B |
50 |
60 |
| LR160-97C |
52 |
60 |
| LR160-104 |
50 |
60 |
| LR160-109 |
50 |
70 |
| LR170-028 |
50 |
70 |
| LT150-131B |
40 |
50 |
| LT150-144 |
40 |
50 |
| 8-94231-307-2 |
50 |
60 |