Intake Throttle Valve
Apply vacuum to vacuum supply tube at top of vacuum diaphragm. Diaphragm should not "leak down" and should move to full turn position at 7.9 in. Hg. See Figure .
Apply vacuum to vacuum supply tube at top of vacuum diaphragm. Diaphragm should not "leak down" and should move to full turn position at 7.9 in. Hg. See Figure .