Diagnostic Aids
An intermittent problem can be caused by misrouted harness, rubbed through wire insulation or broken wire inside insulation. If other DTC(s) are set for components that share the same ground and/or 5-volt reference circuit, check for faulty connections or wiring. PCM 5-volt reference circuits are internally connected within PCM. Also, using FREEZE FRAME data may aid in determining conditions present when DTC was set.