Charging System Light

WARNING: This page is about a different car, the 1998 Acura SLX. However, it is still accessible from the selected car via links, so may be relevant.
  1. Turn ignition on. Charging system light should turn on. If charging system light does not turn on, disconnect generator wiring harness connector. Using a fused jumper wire, ground terminal "L" (White/Green wire) on wiring harness side of connector. See Fig 1.
  2. If charging system light turns on, perform IC regulator test. See IC REGULATOR under BENCH TESTING . If charging system light does not turn on, check charging system light bulb and replace as necessary. If bulb is okay, repair open in White/Green wire.
Fig 1: Identifying Generator Ignition Feed Circuit
G95C34951Courtesy of AMERICAN HONDA MOTOR CO., INC.