Open Loop
When engine is cold, PCM ignores signal from heated oxygen sensor (HO2S). Air/fuel ratio is calculated based on inputs from TPS, ECT and MAF or MAP sensors. System will remain in open loop until HO2S reaches operating temperature, coolant temperature reaches preset temperature, a specific period of time has elapsed after engine starts and engine speed has been greater than a specified RPM since start-up.