LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Isuzu >> 2002 >> Axiom Base, 4WD >> Repair and Diagnosis (Single Page) >> Body & Frame >> Anti-Theft, Power Door Locks & Keyless Entry Systems >> Programming >> Programming New Id Code
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Programming New Id Code

NOTE: This procedure erases all registered ID codes and registers a new ID code.
  1. Make sure that all doors are closed and unlocked. Open driver's side door. In starter key into ignition. Then go to next step.
  2. Turn ignition switch to ACC position and return it to OFF quickly three times. (Must be carried out within five seconds after step 1 is finished) Is action complete? If Yes, then go to next step. If No, then go to step  1 .
  3. Close and open driver side door quickly two times. (Must be carried out within 10 second after step 2 is finished). Is action complete? If Yes, then go to next step. If No, then go back to step  1 .
  4. Turn ignition switch to ACC position and return to OFF position quickly five times. Close and open driver's side door quickly 1 time. (Must be carried out within 10 seconds after step 3 is finished). Is action complete? If Yes, then go to next step. If No, then go back to step  1 .
  5. Control units locks and unlocks the doors one time. Does control unit work normally? If Yes, then go to next step. If No, then go back to step  1 .
  6. Operate lock or unlock button of transmitter. (Must be carried out within 20 seconds after step 5 is finished). Is action complete? If Yes, then go to next step. If No, then go back to  1 .
  7. Control unit locks and unlocks the doors one time. Does control unit work normally? If Yes, then go to next step. If No, then go back to step  1 .
  8. Operate lock or unlock button of the transmitter. (Must be carried out within 20 seconds after step 7 is finished). Is action complete? If Yes, then go to next step. If No, then go back to step  1 .
  9. If registration succeeds, control unit locks and unlocks the doors one time. If registration fails, control unit locks and unlocks the doors three times then go back to step  1 .