Test Description
Number(s) below refer to the step number(s) on the Diagnostic Chart.
- 2. The HO2S should be allowed to cool before performing this test. If the HO2S heater is functioning, the signal voltage will gradually increase or decrease as the sensor element warms. If the heater is not functioning, the HO2S signal will remain near the 470 mV bias voltage.
- 4. This ensures that the ignition feed circuit to the HO2S is not open or shorted. The test light should be connected to a good chassis ground, in case the HO2S low or HO2S heater ground circuit is faulty.
- 5. This checks the HO2S heater ground circuit.
- 6. This checks for an open or shorted HO2S heater element.
- 11. An open HO2S signal or low circuit can cause the HO2S heater to appear faulty. Check these circuits before replacing the sensor.
DTC P0141 - O2 SENSOR HEATER CIRCUIT (BANK 1 SENSOR 2)
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| 1 | Was the "On-Board Diagnostic (OBD-II) System Check" performed? | - | Go to Step 2 | Go to On-Board Diagnostic (OBD-II) System Check |
| 2 |
|
0.1A | Go to Step 3 | Refer to DIAGNOSTIC AIDS |
| 3 | Inspect the fuse for Bank 1 HO2S2 ignition feed. Is the fuse open? |
- | Go to Step 15 | Go to Step 4 |
| 4 |
|
- | Go to Step 5 | Go to Step 7 |
| 5 | Connect the test light between the Bank 1 HO2S2 ignition feed and the Bank 1 HO2S2 heater ground. Does the test light illuminate? |
- | Go to Step 6 | Go to Step 8 |
| 6 |
|
3--6 Ω | Go to Step 9 | Go to Step 10 |
| 7 | Repair the open Bank 1 HO2S2 ignition feed circuit to Bank 1 HO2S 2. Is the action complete? |
- | Verify repair | - |
| 8 | Repair the open Bank 1 HO2S2 heater ground circuit. Is the action complete? |
- | Verify repair | - |
| 9 |
|
- | Verify repair | Go to Step 10 |
| 10 |
|
- | Verify repair | Go to Step 11 |
| 11 |
|
- | Verify repair | Go to Step 12 |
| 12 | Check for a poor Bank 1 HO2S2 low circuit terminal connection at the ECM and replace the terminal if necessary. Did the terminal require replacement? |
- | Verify repair | Go to Step 13 |
| 13 | Check for a poor Bank 1 HO2S2 high circuit terminal connection at the ECM and replace the terminal if necessary. Did the terminal require replacement? |
- | Verify repair | Go to Step 14 |
| 14 | Replace Bank 1 HO2S 2. Is the action complete? |
- | Verify repair | - |
| 15 | Locate and repair the short to ground in Bank 1 HO2S2 ignition feed circuit and replace the faulty fuse. Is the action complete? |
- | Verify repair | - |