Circuit/System Testing
- Start the engine with the J 41413-200 connected to the fuel filler neck. See Special Tools .
- Allow the engine to idle.
- Use the Purge/Seal function to seal the system with a scan tool.
- Command the EVAP canister purge solenoid valve to 30 percent.
- Observe the vacuum/pressure gage on the J 41413-200 and the FTP parameter on the scan tool. See Special Tools .
- Allow the vacuum to increase on the gage of the J 41413-200 until it reaches approximately 16 inches H2O or until the vacuum reached the abort limit on the scan tool. See Special Tools .
- Use the Purge/Seal function to seal the system with a scan tool.
- If the difference between the FTP parameter on a scan tool and the vacuum/pressure gage on the J 41413-200 is more than 1 inch H2O replace the FTP sensor. See Special Tools .
- If the Fuel Tank Pressure Sensor parameter on a scan tool display is less than 3.2 volts, replace the FTP sensor.
IMPORTANT:
Refer to the J 41413-200
operation manual for detailed instructions. See Special Tools
.