Circuit/System Description
The knock sensor (KS) system enables the control module to control the ignition timing for the best possible performance while protecting the engine from potentially damaging levels of detonation. The KS is located on the intake side of the engine block. The KS produces an AC voltage signal that varies depending on the vibration level during engine operation. The control module adjusts the spark timing based on the amplitude and the frequency of the KS signal. The control module receives the KS signal through 2 isolated signal circuits. The control module learns a minimum KS noise level at idle and uses calibrated values for the rest of the RPM range. The control module should monitor a normal KS signal within the noise channel.