LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Jaguar >> 1982 >> XJ-6 L6-4.2L >> Repair and Diagnosis >> Heating and Air Conditioning >> Control Assembly >> Service and Repair
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Control Assembly: Service and Repair


Temperature & Mode Microswitches

Removing

- Disconnect the battery earth lead. Remove the centre console as detailed in operation. Service and Repair





- Remove two bolts, two nuts and associated shakeproof washers (1, Fig. 5) securing mounting plate to heater unit.

- Remove three screws (2, Fig. 5) securing vacuum switches to mounting plate.

- Note positions of vacuum pipes and disconnect from switches.

- Remove circlips and locking rings (3. Fig. 5). Remove mounting plate from studs. Note position of cables and pipes on vacuum switch, and micro-switches before disconnecting.

- To change micro-switch(es), remove secure screws and nuts as necessary.

NOTE: Ensure replacement switches are of correct pattern.

- To change vacuum switch remove two screws securing mounting bracket

Refitting

- Refit mounting plate to studs.

- Refit circlips and locking rings.

- Reconnect the vacuum pipes to their correct positions on switches, and refit the three screws securing the vacuum switches to mounting plate.

- Secure mounting plate to heater unit with the fixing nuts and bolts.

- Refit the centre console.

- Reconnect the battery