LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Jaguar >> 1982 >> XJ6 Base >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Distributors & Ignition Systems - LUCAS Constant Energy Ignition >> Testing >> Amplifier Lead Test >> Tachometer Lead
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Tachometer Lead

Connect ohmmeter leads to tachometer lead and to coil negative terminal. Reading should be 8, 000-12, 000 ohms. If not, replace amplifier.