Section 106 (Climate Control System-General Information): Specification
WARNING: This page is about a different car, the 2002 Jaguar XKR and 2002 Jaguar XK8. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
ppm = parts per million
RECOVERY / RECYCLE / RECHARGE EQUIPMENT - SPECIFICATIONS
| Feature | Requirement |
|---|---|
| Recovery rate | 0,014 - 0,062 m3 / min. (1,36 kg in 20 minutes) |
| Cleaning capability | 15 ppm moisture; 4000 ppm oil; 330 ppm non-condensable gases in air |
| Oil separator | With hermetic compressor and automatic oil return |
| Moisture indicator | Sight-glass type, sensitive to 15 ppm minimum |
| Vacuum pump | Two-stage 0,07 - 0,127 m3 / min. |
| Filter | Replaceable, with moisture indicator |
| Charge | Selectable charge weight and automatic delivery |
| Hoses | Dedicated HFC 134A port connections |
| Charge pressure | Heating element to increase pressure |
LUBRICANTS, FLUIDS, SEALANTS AND ADHESIVES - SPECIFICATIONS
| Unit | Specification |
|---|---|
| Refrigerant | HFC134A |
| Compressor lubricant | Polyalkyleneglycol (PAG) |
CAPACITIES SPECIFICATIONS
| Unit | Specification |
|---|---|
| Refrigerant charge weight | 650 +/- 50g |
| Compressor lubricant capacity | 160 - 200 ml |