Midtronics Testing
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2003 Jaguar XJR, 2003 Jaguar XJ8, 2003 Jaguar XJ, 2002 Jaguar XJR, and 2002 Jaguar XJ8. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Remove surface charge by allowing vehicle to set for 24 hours or by turning on head lamps for 5 minutes before performing Midtronics testing. Do not connect the tester to any other circuits or chassis points.
NOTE:
Special tool required: Midtronics Battery Tester.
- Ensure battery terminals are clean. Connect the red lead to the positive post and black lead to the negative post. Rock the leads back and forth on the battery terminals to ensure a good connections.
- Using the arrow buttons on the tester, scroll to the batteries Cold Cranking Amperage (CCA) rating.
- Press the TEST button that corresponds to the correct battery temperature. If battery temperature is above 32°F (0°C) press the SUN button. If battery temperature is below 32°F (0°C) press the ICE CRYSTAL button.
- Perform service as necessary based of test results displayed on tester screen. See MIDTRONICS TEST RESULTS/SERVICE REQUIRED table.
MIDTRONICS TEST RESULTS/SERVICE REQUIRED
| Test Results | Service Required | ||||
|---|---|---|---|---|---|
| GOOD BATTERY | Return To Service | ||||
| GOOD - RE-CHARGE | Fully Charge Battery & Return To Service | ||||
| CHARGE & RE-TEST | (1) Fully Charge Battery & Retest | ||||
| REPLACE BATTERY Or BAD CELL BATTERY | (2) Replace Battery | ||||
| UNABLE TO TEST | Disconnect Battery From Vehicle & Retest | ||||
|
|||||