Control Panel Fault Code Listing

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2006 Jaguar XKR, 2006 Jaguar XK8, 2005 Jaguar XKR, 2005 Jaguar XK8, and 2004 Jaguar XKR. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Reference fault code #23*: In ambient temperatures below 0°C, this code may be logged because the low ambient causes a temporary low gas pressure.
NOTE: Where the ambient temperature rises above 40°C, with the engine close to overheating, electrical feed to the compressor clutch may be cut and code #23 registered.
Control Panel Fault Code Listing

Condition Possible Source Action
0 Normal operation no fault codes present None Wait 30 seconds for system self-check.
11 Motorized in-car aspirator malfunction Harness / connector fault
Sensor open / short circuit
Panel fault codes are not stored for motorized in-car aspirator motor failure.
12 Ambient temperature sensor malfunction Harness / connector fault
Sensor open / short circuit
After rectification, disconnect the vehicle battery for 10 seconds to reset the system.
13 Evaporator temperature sensor malfunction Harness / connector fault
Sensor open / short circuit
Refer to PDU
14 Water temperature input malfunction Instrument cluster output Refer to PDU
15 Heater matrix temperature sensor malfunction Harness / connector fault
Sensor open / short circuit
Refer to PDU
21 Solar sensor Sensor open /short circuit Refer to PDU
22 Compressor lock signal fault Low refrigerant charge, low compressor oil level, loose drive belt
Harness / connector fault
Adjust items as required
23 Refrigerant pressure switch malfunction Harness / connector fault
Switch open / short circuit
Refer to PDU
23 Refrigerant pressure low refrigerant charge * Leak from damaged pipe or joint Rectify as required and recharge system
24 Face vent demand potentiometer fault Potentiometer open / short circuit
Harness / connector fault
Refer to PDU
31 LH fresh / recirc. potentiometer fault Harness / connector fault
In certain circumstances the servo motor may over-travel and cause further logged faults. This may be cured, following fault rectification, by cycling the ignition ON-OFF-ON 3 times
Refer to PDU
32 RH fresh / recirc. potentiometer fault Harness / connector fault
In certain circumstances the servo motor may over-travel and cause further logged faults. This may be cured, following fault rectification, by cycling the ignition ON-OFF-ON 3 times
Refer to PDU
33 Cool air bypass potentiometer fault Harness / connector fault
In certain circumstances the servo motor may over-travel and cause further logged faults. This may be cured, following fault rectification, by cycling the ignition ON-OFF-ON 3 times
Refer to PDU
34 Defrost vent potentiometer fault Harness / connector fault
In certain circumstances the servo motor may over-travel and cause further logged faults. This may be cured, following fault rectification, by cycling the ignition ON-OFF-ON 3 times
Refer to PDU
35 Centre vent potentiometer fault Harness / connector fault
In certain circumstances the servo motor may over-travel and cause further logged faults. This may be cured, following fault rectification, by cycling the ignition ON-OFF-ON 3 times
Refer to PDU
36 Foot vent potentiometer fault Harness / connector fault
In certain circumstances the servo motor may over-travel and cause further logged faults. This may be cured, following fault rectification, by cycling the ignition ON-OFF-ON 3 times
Refer to PDU
41 LH fresh / recirc. motor fault Harness / connector fault
Servo motor seized or sticking
Flap seized or sticking
Refer to PDU
42 RH fresh / recirc. motor fault Harness / connector fault
Servo motor seized or sticking
Flap seized or sticking
Refer to PDU
43 Cool air bypass motor fault Harness / connector fault
Servo motor seized or sticking
Flap seized or sticking
Refer to PDU
43 Cool Air bypass motor fault Harness / connector fault
Servo motor seized or sticking
Flap seized or sticking
Refer to PDU
44 Defrost vent motor fault Harness / connector fault
Servo motor seized or sticking
Flap seized or sticking
Refer to PDU
45 Centre vent motor fault Harness / connector fault
Servo motor seized or sticking
Flap seized or sticking
Refer to PDU
46 Foot vent motor fault Harness / connector fault
Servo motor seized or sticking
Flap seized or sticking
Refer to PDU