Control Switch & Motor Test
- Connect test light between terminals of Orange and Yellow wires. Operate control switch up and down. If test light glows in both switch positions, wires, individual door and master switches are not defective.
- Disconnect White and Green motor leads at terminal plate, and connect to Green and White leads. Operate master switch. If window goes up and down, motor is okay, but switch is defective. If motor does not operate, remove trim panel and check connections and leads to motor. If motor operates, switch is defective.