Test 10C - Repairing Open GND To Electro/Mech Inst CLSTR
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For wiring diagram, see WIRING DIAGRAMS
article in this section.
CAUTION:
Always turn ignition off prior to disconnecting or connecting any module connector.
- Using DRB, stop actuation test. Turn ignition off. Disconnect Electro/Mechanical Instrument Cluster (MIC) connector. Check connector, and clean or repair connector as necessary. Perform TEST VER-1B . If connector is okay, go to next step.
- Using DRB in ohmmeter mode, check resistance of signal ground circuit (Black/Light Green wire) at MIC connector terminal No. 7. If resistance is more than 5 ohms, repair open Black/Light Green wire. Perform TEST VER-1B . If resistance is less than 5 ohms, go to next step.
- Remove faulty gauge and inspect MIC printed circuit. If MIC printed circuit is okay, replace faulty gauge. Perform TEST VER-1B . If MIC printed circuit is defective, replace MIC printed circuit. Perform TEST VER-1B .