Checking For Speed Control Denied Message
At this time speed control switch and servo functions appear to operate properly. Using scan tool, monitor speed control output status. Road test vehicle at speeds more than 35 MPH. Attempt to set speed control. See SCAN TOOL DENIED STATUS table. Items listed in table will not allow speed control to set. The last or most recent cause for speed control not to set is indicated by denied status. If speed control sets, no problem is indicated at this time.
SCAN TOOL DENIED STATUS
| Denied Message | Reason |
|---|---|
| ON/OFF | PCM Does Not See An ON Signal From Switch |
| SPEED | PCM Does Not See Vehicle Speed More Than 36 MPH |
| RPM | Engine RPM Is Excessively High |
| BRAKE | Brake Switch Sense Circuit Is Open Indicating Brakes Are Applied |
| P/N | Park/Neutral Switch Sense Circuit Is Grounded Indicating That Transmission Is In Park Or Neutral |
| RPM/SPD | PCM Senses Excessive Engine RPM For A Given Vehicle Speed |
| SOL FLT | PCM Senses A Servo Solenoid Circuit Trouble Code That Is Maturing Or Set In Memory |