Ambient Temperature Sensor Fault Codes
The outside temperature function is supported by the ambient temperature sensor (ATS), a signal and ground circuit hardwired to the PCM, and the EVIC display.
If the EVIC display indicates 54°C (130°F) or the ATS sense circuit is shorted to ground, the temp display will be 54°C (130°F) to indicate a SHORT circuit condition.
If the EVIC display indicates -40°C (-40°F) or the ATS sense circuit is open, the temp display will be -40°C (-40°F) to indicate an OPEN circuit condition.
If there is an OPEN or SHORT circuit condition, it must be repaired before the EVIC VFD can be tested.
The ATS is supported by the PCM. Ambient Temperature Sensor DTCs will be recorded in the PCM. Test the ATS circuits using the diagnostics in the Powertrain Diagnostics Procedures article.