Charging System (Service Information): Specifications: Generator

MANUFACTURER  ENGINE  NOMINAL RATING  MINIMUM OUTPUT (AMPS) (@ SPECIFIED TEST CONDITIONS) 
MITSUBISHI ELECTRIC 1.8, 2.0, 2.4L 120A 70A
MITSUBISHI ELECTRIC 1.8, 2.0, 2.4L 140A 90A
MITSUBISHI ELECTRIC 2.0L TURBO DIESEL 150A 100A
TEST CONDITIONS 
1. Engine RPM : 2500 RPM (ENGINE HOT)
2. Voltage Output : 13.0 - 16.0 V