Set Condition
- When the PCM receives a Brake Switch 1 ON (Pressed) signal without receiving a Brake Switch 2 ON (Pressed) signal, a counter will increment. Once the counter reaches a calibrated number of instances, the fault will set.
- If the PCM receives an ON signal from Brake Switch 2 along with the Brake Switch 1 ON signal at any time before the fault matures, the counter will start over at zero.