ETACS Function
- Rear window defogger and side mirror defogger.
Time specification:
T1: 6+/-3
- Seat belt warning:
T1: 6 +/- 1.5 sec.
- Burglar alarm:
- Horn operates ON/OFF for 0.5 second while it is armed.
- Arm/disarm is operated by only the remote keyless entry.
- If any of entrances aren't opened for 30 second in disarm state.
If will generate the door lock output, and it is armed.
- Upon receiving the TX lock signal in the arm state, it doesn't generate lock output signal, but it generates the hazard lamp output 1 time for 1 second.
- Upon receiving the TX unlock signal in the disarm state, it generates unlock output signal, hazard lamp output twice.
- Delayed room lamp:
Time specification
T1: 4-5 sec.
T2: 20 +/- 5 min.
- Upon the door open with the keyless switch OFF, the room lamp turns on for T2.
The room lamp declines to 75% at once when the door close.
- Upon the door switch OFF with the ACC is OFF the room lamp declines 75% to 0% for T1.
Upon the door switch OFF with the ACC is ON the room lamp turns on for T1.
- Upon the door open with the keyless switch OFF, the room lamp turns on for T2.
- Ignition key reminder.
- Battery saver.
- Power window timer:
Time specification:
T: 30 +/- 5 sec.
- Lighter ajar:
Alarm occurs while the door opened when the TNS switch is ON and IG switch is ON.
- Central door lock / unlock:
- Key reminder unlock:
Time specification:
T1: less than 0.1 sec
T2: 1.0 sec.
T3: 0.5 sec.
T4: Max 0.5 sec.
- Remote keyless entry system
- Door lock:
Time specification:
T1: 1.0 +/- 0.2 sec.
- Door unlock:
Time specification:
T1: 1.0 +/- 0.2 sec.
- Door lock:
- Remote keyless entry code saving.
- Store the transmitter code by using Hi-scan pro.
- Connector pin arrangement.