ETACS Function
- Rear window defogger and side mirror defogger.
Time specification
T1; 6+/-3
- Seat belt warning
T1 : 6 +/- 1.5 sec.
- Burglar alarm
- Horn operates ON/OFF for 0.5 second while it is armed.
- Arm/disarm is operated by only the remote keyless entry.
- If any of entrances aren't opened for 30 second in disarm state, it will generate the door lock output, and it is armed.
- Upon receiving the TX lock signal in the arm state, it doesn't generate lock output signal, but it generates the hazard lamp output 1 time for 1 second.
- Upon receiving the TX unlock signal in the disarm state, it generates unlock output signal, hazard lamp output twice.
- Decayed room lamp
Time specification
T1 : 4-5 sec.
T2 : 20 +/- 5 min.
- Upon the door open with the keyless switch OFF, the room lamp turns on for T2.
The room lamp declines to 75% at once when the door close.
- Upon the door switch OFF with the ACC is OFF the room lamp declines 75% to 0% for T1.
- Upon the door switch OFF with the ACC is ON the room lamp turns on for T1.
- Upon the door open with the keyless switch OFF, the room lamp turns on for T2.
- Ignition key reminder
- Battery saver.
- Power window timer
Time specification
T : 30 +/- 5 sec.
- Lighter ajar
Alarm occurs while the door opened when the TNS switch is ON and IG switch is ON.
- Central door lock/unlock
- Key reminder unlock
Time specification
T1 : less than 0.1 sec
T2 : 1.0 sec.
T3 : 0.5 sec.
T4 : Max 0.5 sec.
- Remote keyless entry system
- Door lock
Time specification
T1 : 1.0 +/- 0.2 sec.
- Door unlock
Time specification
T1 : 1.0 +/- 0.2 sec.
- Door lock
- Remote keyless entry code saving
- Store the transmitter code by using Hi-scan pro.
- Connector pin arrangement.