CHARGING SYSTEM SPECIFICATION

Items Specification
3.8L
Generator Type Battery voltage sensing
Rate voltage 13.5 V, 130A
Speed in use 1,000-18,000 RPM
Voltage regulator IC regulator built-in type
Regulator setting voltage 14.2-14.8 V
Temperature compensation -4 ± 4 mV / °C
Battery Type MF 68AH (3.3L) / MF 80AH (3.8L)
Cold cranking amperage [at -18°C (-0.4°F)] 600 A (3.3L) / 630 A (3.8L)
Reserve capacity 110 min (3.3L) / 130 min (3.8L)
Specific gravity [at 20°C (68°F)] 1.280 ± 0.01
Maximum parasitic draw amount (dark current) 31mA
NOTE:
  • COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
  • RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7° (80.1°F).