Evaporative Emission Control System: Inspection

  1. Disconnect the vacuum hose from the throttle body, and connect a vacuum pump to the vacuum hose.
  2. Check the following points when the engine is cold [engine coolant temperature 60°C (140°F) or below] and when it is warm [engine coolant temperature 80°C (176°F) or higher].

WHEN ENGINE IS COLD 

ENGINE COLD RESULT REFERENCE

Engine operating condition Applied vacuum Result
Idling 50 kPa (7.3 psi) Vacuum is held
3,000 RPM

WHEN ENGINE IS WARM 

ENGINE WARM RESULT REFERENCE

Engine operating condition Applied vacuum Result
Idling 50 kPa (7.3 psi) Vacuum is held
Within 3 minutes after engine start at 3,000 RPM Try to apply vacuum Vacuum is released
After 3 minutes have passed after engine start at 3,000 RPM 50 kPa (7.3 psi) Vacuum will be held momentarily, after which, it will be released