Ecu Connector: Input/Output(Abs): Notes
ECU CONNECTOR TERMINALS REFERENCE CHART
| Wire No. | Designation | Current | max.permissibie wire resistance R_L (mΩ) | min.leakage resistance R_P (kΩ) | |
|---|---|---|---|---|---|
| max | min | ||||
| 1 | Ground for recirculation pump | 20~39 A | 10 A | 10 | |
| 4 | Ground for solenoid valves and ECU | 5~15 A | 2.5 A | 10 | |
| 2 | Voltage supply for pump motor | 20~39 A | 10 A | 10 | 200 |
| 3 | Voltage supply for solenoid valves | 5~15 A | 2 A | 10 | 200 |
| 18 | Voltage for hybrid ECU | 1 A | 500 mA | 60 | 200 |
| 5,10,17,19 | signal wheel speed sensor FL, FR, RL,RR | 6 mA | 16 mA | 250 | 200 to ground 1.5M to bat |
| 16,9,6,8 | Voltage supply for the active wheel speed sensor FL,FR, RL, RR | 6 mA | 16 mA | 250 | 200 to ground 1.5M to bat |
| 14,24 | wheel speed sensor output (FR, RL) | 20 mA | 10 mA | 250 | 200 |
| 11 | Diagnostic wire K | 6 mA | 3 mA | 250 | 200 |
| 22 | ABS-warning lamp actuation | 30 mA | 5 mA | 250 | 200 |
| 12 | EBD-warning lamp actuation | 30 mA | 5 mA | 250 | 200 |
| 20 | brake light switch | 10 mA | 5 mA | 250 | 200 |
| 15 | CAN Low | 30 mA | 20 mA | 250 | 200 |
| 26 | CAN High | 30 mA | 20 mA | 250 | 200 |