Memory Storage Operation By Keyless
- If "ID1" or "ID2" is received during keyless lock operation, record seat and pedal position in keyless code, (there is no buzzer output during memory storage operation by keyless)
- Memory storage operation is allowed for a single ID after a change of IG from "on" → "off".
- Any one of the following conditions will prevent keyless Memory storage operation.
- When "P" position switch is not on.
- When Vehicle Speed in CAN BUS data transmitted from CLUSTER is "3km/h" or faster.
- When seat and pedal is manipulated by CAN BUS and manual switch.
- When IG transmitted from IPM is other than off.