Checking Of Short Or Open Circuit
Refer to the following tips for checking of short or open circuit.
- Shorting bar is located on the upper side of pin number from 2 to 25 of SRSCM connector.
- When checking for a short circuit, the shorting bar must be opened. Use a plastic clip to put into as a shorting bar opener for disconnecting shorting bar.
- Use SST Dummy adapter (0957A-2G000) to measure resistance or voltage for checking of short or open circuit. Plug it into DAB (BPT) connector to avoid enlarging or damaging the connector pins.