P0036: Ho2S Heater Control Circuit (Bank1/Sensor2): DTC Detecting Condition
DTC DETECTING CONDITION CHART
| Item |
Detecting Condition |
Possible Cause |
| DTC Strategy |
- Evaluate O2 sensor element temperature via measuring element resistance
|
- Related fuse blown or missing
- Heater control circuit open or short
- Power supply circuit open or short
- Contact resistance in connectors
- Faulty HO2S
|
| Enable Conditions |
- No relevant failure
- Sensor preheating and full heating phases finished
- Time after start elapsed: 240 sec.
- 11V < Battery voltage < 16V
- 1% < Heater power < 99%
- Exhaust gas temperature model < 650°C (1202°F)
|
| Threshold Value |
- HO2S Element Resistance >1100 Ω [Catalyst Temperature < 550°C (1,022°F)]
|
| Diagnostic Time |
|
| Fail-Safe |
- EVAP emission control function is controlled in minimum operation mode
|
| Mil On Condition |
|