P0125: Insufficient Coolant Temperature For Closed Loop Fuel Control: Specification
[ECTS]
TEMPERATURE SPECIFICATION
| Temperature | ECTS Resistance (Ω) | Temperature | ECTS Resistance (Ω) | ||
|---|---|---|---|---|---|
| (°C) | (°F) | (°C) | (°F) | ||
| -20 | -4 | 14.13-16.83 | 40 | 104 | 1.15 |
| 0 | 32 | 5.79 | 60 | 140 | 0.59 |
| 20 | 68 | 2.31-2.59 | 80 | 176 | 0.32 |
[THERMOSTAT]
TEMPERATURE SPECIFICATION
| Thermostat | Normal Parameter |
|---|---|
| Valve Opening Temp. | 82°C (179.6°F) |
| Valve Closing Temp. | 77°C (170.6°F) |
| Full Open Lift | Above 10mm at 95°C (203°F) |