Charging System
CHARGING SYSTEM SPECIFICATION
| Items | Specification | |
|---|---|---|
| 3.8L | ||
| Generator | Type | Battery voltage sensing |
| Rate voltage | 13.5V, 150A | |
| Speed in use | 1,000 ~ 18,000 rpm | |
| Voltage regulator | IC regulator built-in type | |
| Regulator setting voltage | 14.2 ~ 14.8V | |
| Temperature compensation | -4 ± 4 mV/°C | |
| Battery | Type | MF 80A |
| Cold cranking amperage [at -18°C(-0.4°F)] | 630 | |
| Reserve capacity | 130 min | |
| Specific gravity [at 20°C (68°F)] | 1.280 ± 0.01 | |
| Maximum parasitic draw amount (dark current) | 31mA | |
NOTE:
- COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
- RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7°C (80.1°F).