Home >> Kia >> 2012 >> Soul Base, Standard >> Repair and Diagnosis (Single Page) >> Engine Performance >> Engine Control Systems >> Engine Control System - 1.6L >> Engine Control Module (ECM) >> Schematic Diagrams >> ECM Terminal And Input/Output signal (A/T) >> ECM Terminal Input/Output Signal (A/T) >> Connector (EGGA-A)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Connector (EGGA-A)

Pin No. Description Condition Type Level
1 Injector (Cylinder #1) [High] control output Relay ON/OFF DC voltage 71V
2 Injector (Cylinder #4) [High] control output Relay ON/OFF DC voltage 71V
3 Injector (Cylinder #2) [High] control output Relay ON/OFF DC voltage 71V
4 Injector (Cylinder #3) [High] control output Relay ON/OFF DC voltage 71V
5 -      
6 -      
7 Purge Control Solenoid Valve (PCSV) control output Relay OFF DC voltage Battery voltage
Relay ON Max. 1.76V
8 Start relay control output Relay OFF DC voltage Battery voltage
Relay ON Max. 2.64V
9 -      
10 Power supply (+5V) IG OFF DC voltage Max. 0.5V
IG ON 4.9 ~ 5.1V
11 Sensor power (+5V) IG OFF DC voltage Max. 0.5V
IG ON 4.9 ~ 5.1V
12 Throttle Position Sensor (TPS) 1 signal input Idle Analog 0.33 ~ 4.72 V
13 Sensor ground Idle DC voltage Max. 50mV
14 -      
15 Sensor power (+5V) IG OFF DC voltage Max. 0.5V
IG ON 4.9 ~ 5.1V
16 -      
17 -      
18 Sensor power (+5V) IG OFF DC voltage Max. 0.5V
IG ON 4.9 ~ 5.1V
19 Sensor power (+5V) IG OFF DC voltage Max. 0.5V
IG ON 4.9 ~ 5.1V
20 Ground Idle DC voltage Max. 50mV
21 -      
22 -      
23 -      
24 Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 1] heater control output Relay OFF DC voltage Battery voltage
Relay ON Max. 1.65V
25 Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 2] heater control output Relay OFF DC voltage Battery voltage
Relay ON Max. 1.65V
26 -      
27 -      
28 -      
29 -      
30 A/C pressure switch signal input ON DC voltage Battery voltage
OFF Max. 2V
31 A/C switch signal input ON DC voltage Battery voltage
OFF Max. 2V
32 Sensor ground Idle DC voltage Max. 50mV
33 -      
34 Throttle Position Sensor (TPS) 2 signal input Idle Analog 0.55 ~ 4.37 V
35 -      
36 -      
37 -      
38 -      
39 -      
40 -      
41 Sensor ground Idle DC voltage Max. 50mV
42 -      
43 -      
44 -      
45 -      
46 -      
47 -      
48 -      
49 -      
50 -      
51 Alternator PWM signal output Idle Pulse High: Battery voltage
Low: Max. 1.5V
52 -      
53 Brake switch signal input ON DC voltage Battery voltage
OFF Max. 2.25V
54 Accelerator Position Sensor (APS) 1 signal input Idle Analog 0.674 ~ 4.379 V
55 -      
56 Accelerator Position Sensor (APS) 2 signal input Idle Analog 0.261 ~ 2.204 V
57 -      
58 -      
59 -      
60 Sensor ground Knocking Variable  
Normal Frequency  
61 Knock Sensor (KS) signal input Knocking Variable  
Normal Frequency  
62 Sensor ground Idle DC voltage Max. 50mV
63 Sensor ground Idle DC voltage Max. 50mV
64 Injector (Cylinder #1) [Low] control output Relay OFF DC voltage 71V
Relay ON Max. 1.0V
65 Injector (Cylinder #4) [Low] control output Relay OFF DC voltage 71V
Relay ON Max. 1.0V
66 Injector (Cylinder #2) [Low] control output Relay OFF DC voltage 71V
Relay ON Max. 1.0V
67 Injector (Cylinder #3) [Low] control output Relay OFF DC voltage 71V
Relay ON Max. 1.0V
68 -      
69 -      
70 -      
71 -      
72 -      
73 -      
74 -      
75 -      
76 -      
77 Fuel Tank Pressure Sensor (FTPS) signal input Idle Analog 0.3343 ~ 0.4667V
78 Fuel Level signal input Idle Analog 0.193 ~ 4.0V
79 Cruise control switch signal      
80 -      
81 -      
82 Engine Coolant Temperature Sensor (ECTS) signal input Idle Analog 0.270 ~ 4.77V
83 VS-/IP- (Common Ground for VS, IP) Idle DC voltage Max. 50mV
84 VS+ (NERNST Cell Voltage) Idle Analog 0 ~ 5.1V
85 Fuel Pressure Control Valve (FPCV) [Low] control output Relay OFF DC voltage 16V
Relay ON Max. 1.0V
86 Fuel Pressure Control Valve (FPCV) [High] control output Relay ON/OFF DC voltage 16V
87 -      
88 -      
89 -      
90 -      
91 -      
92 -      
93 -      
94 -      
95 -      
96 -      
97 -      
98 -      
99 -      
100 -      
101 -      
102 -      
103 Heated Oxygen Sensor (HO2S) [Bank 1 / Sensor 2] signal input Engine Analog Rich: 0.6 ~ 1.0V
Running Lean: Max. 0.4V
104 Rc/Rp (Pump Cell Voltage) Idle Analog 0 ~ 5.1V
105 Rc (Compensative Resistance) Idle Analog 0 ~ 5.1V