Body Control Module (BCM): Specifications: Notes
ITEM SPECIFICATIONS CHART
| Item | Requirement | Remark |
|---|---|---|
| Rated voltage | DC 12V | Shall activate normally in these range. |
| Operating voltage range | DC 9 ~ 16V | |
| Operating temperature range | -30°C ~ +75°C | |
| Storage temperature range | -40°C ~ +85°C | |
| Max humidity in use | 95% | |
| High voltage resistance | 24V | |
| Insulation resistance | 100M ohm or more (measured with 500V MEGGER) | Specify as well as parts that insulation like PCB, moisture-proof COATING is required |
| Dark Current | Max 4mA (KEYLESS) Max 3mA (NON-KEYLESS) |
Measure when the state, all output loads are OFF and there are no Input SW (including TX operation) changes, continues 2 sec. |
| Voltage drop | 1.2V or less | Output terminals for TAIL LAMP RELAY, POWER WINDOW RELAY, SAFETY POWER WINDOW, BURGLAR ALARM RELAY shall be 2.0V or less |