DTC P0462: Fuel Level Sensor 'A' Circuit Low Input: Specification
FUEL LEVEL SENSOR 'A' CIRCUIT LOW INPUT SPECIFICATION
| Digital Cluster | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Float position | S/F | 12/12 | 11/12 | 10/12 | 9/12 | 8/12 | 7/12 | 6/12 | 5/12 | 4/12 | 3/12 | 2/12 | W'G | G/E | S/E |
| Sender-Resistance (Ω) | 8.0±1 | 15.0±1 | 29.1±1 | 43.2±1 | 57.3±1 | 71.4±1 | 85.5±1 | 99.6±1 | 113.7±1 | 127.8±1 | 141.9±1 | 156.0±1 | 170.1±1 | 184.0±1 | 200.0±1 |
| Fuel Height From Bottom | 146.4±2 | 135.9±2 | 122.4±2 | 110.5±2 | 99.9±2 | 90.3±2 | 81.6±2 | 73.1±2 | 65.1±2 | 56.3±2 | 48.8±2 | 38.0±2 | 27.4±1.5 | 23.4±1.5 | 19.4±1.5 |
| F/Tank VOL.(L) (Reference) | 78.4 | 74.3 | 68.9 | 63.6 | 58.4 | 53.0 | 47.7 | 42.5 | 37.4 | 31.6 | 26.6 | 19.4 | 12.5 | 10.0 | 7.5 |
FUEL LEVEL SENSOR 'A' CIRCUIT LOW INPUT SPECIFICATION
| Analog Cluster | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Floa position | S/F | G/F | 7/8 | 6/8 | 5/8 | 1/2 | 3/8 | 2/8 | 1/8 | W'G | G/E | S/E |
| Sender-Resistance (Ω) | 8.0±1 | 15.0±1 | 36.0±1 | 57.3±1 | 78.5±1 | 99.6±1 | 120.7±1 | 141.9±1 | 156.0±1 | 170.0±1 | 184.0±1 | 200.0±2 |
| Fuel Height From Bottom | 146.4±2 | 135.9±2 | 116.3±2 | 99.9±2 | 86.0±2 | 73.1±2 | 60.7±2 | 48.8±2 | 38.0±2 | 27.4±1.5 | 23.4±1.5 | 19.4±1.5 |
| F/Tank VOL.(L) (Reference) | 78.4 | 74.3 | 66.3 | 58.4 | 50.4 | 42.5 | 34.5 | 26.6 | 19.4 | 12.5 | 10.0 | 7.5 |