Connector [K]
WARNING: This page is about a different variant/trim than selected.
| Pin No. | Description | Condition | Type | Level |
|---|---|---|---|---|
| 1 | ECM ground | Idle | DC | Max. 50mV |
| 2 | ECM ground | Idle | DC | Max. 50mV |
| 3 | ECM ground | Idle | DC | Max. 50mV |
| 4 | Battery power (B+) | IG OFF | DC | Max. 1.0V |
| IG ON | Battery voltage | |||
| 5 | Battery power (B+) | IG OFF | DC | Max. 1.0V |
| IG ON | Battery voltage | |||
| 6 | Battery power (B+) | IG OFF | DC | Max. 1.0V |
| IG ON | Battery voltage | |||
| 7 | Battery power (B+) | IG OFF | DC | Max. 1.0V |
| IG ON | Battery voltage | |||
| 8 | Sensor ground | Idle | DC | Max. 50mV |
| 9 | Sensor ground | Idle | DC | Max. 50mV |
| 10 | Sensor ground | Idle | DC | Max. 50mV |
| 11 | - | |||
| 12 | - | |||
| 13 | - | |||
| 14 | - | |||
| 15 | - | |||
| 16 | Sensor ground | Idle | DC | Max. 50mV |
| 17 | - | |||
| 18 | - | |||
| 19 | RCV control solenoid valve control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.76V | |||
| 20 | A/C compressor relay control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.0V | |||
| 21 | - | |||
| 22 | CVVT Oil Control Valve (OCV) [Bank 1/Intake] control output | Idle | Pulse | High: Battery voltage |
| Low: Max. 1.65V | ||||
| 23 | - | |||
| 24 | Cooling fan relay [PWM] control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.76V | |||
| 25 | - | |||
| 26 | - | |||
| 27 | Fuel pump relay control output (Smart key type) | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.44V | |||
| 28 | - | |||
| 29 | Ignition switch signal input | IG OFF | DC | Max. 1.0V |
| IG ON | Battery voltage | |||
| 30 | Sensor ground | Idle | DC | Max. 50mV |
| 31 | - | |||
| 32 | - | |||
| 33 | - | |||
| 34 | - | |||
| 35 | - | |||
| 36 | Sensor ground | Idle | DC | - |
| 37 | Sensor ground | Idle | DC | Max. 50mV |
| 38 | - | |||
| 39 | Alternator target voltage data signal output (COM) | Idle | Pulse | High: Battery voltage |
| Low: Max. 0.6V | ||||
| 40 | - | |||
| 41 | Start relay control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 2.64V | |||
| 42 | - | |||
| 43 | Sensor power (+5V) | IG OFF | DC | Max. 0.5V |
| IG ON | 4.9 - 5.1V | |||
| 44 | Sensor power (+5V) | IG OFF | DC | Max. 0.5V |
| IG ON | 4.9 - 5.1V | |||
| 45 | - | |||
| 46 | - | |||
| 47 | - | |||
| 48 | - | |||
| 49 | - | |||
| 50 | CVVT Oil Control Valve (OCV) [Bank 1/Exhaust] control output | Idle | Pulse | High: Battery voltage |
| Low: Max. 1.65V | ||||
| 51 | Battery power (B+) | IG OFF | DC | Max. 1.0V |
| IG ON | Battery voltage | |||
| 52 | Sensor ground | Idle | DC | Max. 50mV |
| 53 | - | |||
| 54 | A/C Pressure Transducer (APT) signal input | A/C ON | Analog | 0.348 - 4.63 V |
| 55 | - | |||
| 56 | Intake Temperature Sensor (IATS) signal input | Idle | Analog | 0.209 - 4.756V |
| 57 | Manifold Absolute Pressure Sensor (MAPS) signal input | Idle | Analog | 0.6683 - 4.346V |
| 58 | Sensor ground | Knocking | Variable | |
| Normal | Frequency | |||
| 59 | VS+ (NERNST Cell Voltage) | Idle | Analog | 0 - 5.1V |
| 60 | Rc (Compensative Resistance) | Idle | Analog | 0 - 5.1V |
| 61 | LIN communication signal input | |||
| 62 | CCP-CAN [Low] | RECESSIVE | Pulse | 2.0 - 3.0V |
| DOMINANT | 0.5 - 2.25V | |||
| 63 | C-CAN [Low] | RECESSIVE | Pulse | 2.0 - 3.0V |
| DOMINANT | 0.5 - 2.25V | |||
| 64 | - | |||
| 65 | - | |||
| 66 | Sensor power (+5V) | IG OFF | DC | Max. 0.5V |
| IG ON | 4.9 - 5.1V | |||
| 67 | - | |||
| 68 | RCV control solenoid valve control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.76V | |||
| 69 | - | |||
| 70 | - | |||
| 71 | Fuel pump relay control output (NON-Smart key type) | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.44V | |||
| 72 | - | |||
| 73 | - | |||
| 74 | Throttle Position Sensor (TPS) 2 signal input | Idle | Analog | 0.55 - 4.37 V |
| 75 | - | |||
| 76 | Fuel Level signal input | Idle | Analog | 0.193 - 4.0V |
| 77 | Accelerator Position Sensor (APS) 2 signal input | Idle | Analog | 0.261 - 2.204 V |
| 78 | Rail Pressure Sensor (RPS) signal input | Idle | Analog | 0.43 - 3.46V |
| 79 | Knock Sensor (KS) signal input | Knocking | Variable | |
| Normal | Frequency | |||
| 80 | VS-/IP- (Common Ground for VS, IP) | Idle | DC | Max. 50mV |
| 81 | Rc/Rp (Pump Cell Voltage) | Idle | Analog | 0 - 5.1V |
| 82 | Engine speed signal output | |||
| 83 | Immobilizer communication line | When transmitting | Pulse | High: Min. 8.4V(at 14V) |
| Low: Max. 6.44V(at 14V) | ||||
| 84 | CCP-CAN [High] | RECESSIVE | Pulse | 2.0 - 3.0V |
| DOMINANT | 2.75 - 4.5V | |||
| 85 | C-CAN [High] | RECESSIVE | Pulse | 2.0 - 3.0V |
| DOMINANT | 2.75 - 4.5V | |||
| 86 | Sensor power (+5V) | IG OFF | DC | Max. 0.5V |
| IG ON | 4.9 - 5.1V | |||
| 87 | Sensor power (+5V) | IG OFF | DC | Max. 0.5V |
| IG ON | 4.9 - 5.1V | |||
| 88 | Sensor power (+5V) | IG OFF | DC | Max. 0.5V |
| IG ON | 4.9 - 5.1V | |||
| 89 | Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 1] heater control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.65V | |||
| 90 | - | |||
| 91 | Heated Oxygen Sensor (HO2S) [Bank 1/Sensor2] heater control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.65V | |||
| 92 | - | |||
| 93 | - | |||
| 94 | Purge Control Solenoid Valve (PCSV) control output | Relay OFF | DC | Battery voltage |
| Relay ON | Max. 1.76V |