Circuit Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
O2 sensor (up) connector | 1 (Virtual Ground) | Chassis ground | - | ∞ (infinite)Ω |
| O2 sensor (UP) connector | 2 (Nearest Voltage) | Chassis ground | - | ∞ (infinite)Ω | |
| O2 sensor (UP) connector | 3 (Current Pump) | Chassis ground | - | ∞ (infinite)Ω | |
| O2 sensor (UP) connector | 4 (Current Adjust) | Chassis ground | - | ∞ (infinite)Ω | |
| O2 sensor (UP) connector | 1 (Virtual Ground) | ECM connector | 43 (Virtual Ground) | Approx. below 1Ω | |
| O2 sensor (UP) connector | 2 (Nearest Voltage) | ECM connector | 58 (Nearest Voltage) | Approx. below 1Ω | |
| O2 sensor (UP) connector | 3 (Current Pump) | ECM connector | 59 (Current Pump) | Approx. below 1Ω | |
| O2 sensor (UP) connector | 4 (Current Adjust) | ECM connector | 44 (Current Adjust) | Approx. below 1Ω | |
|
O2 sensor (up) connector | 1 (Virtual Ground) | Chassis ground | - | Approx. 0V |
| O2 sensor (up) connector | 2 (Nearest Voltage) | Chassis ground | - | Approx. 0V | |
| O2 sensor (UP) connector | 3 (Current Pump) | Chassis ground | - | Approx. 0V | |
| O2 sensor (UP) connector | 4 (Current Adjust) | Chassis ground | - | Approx. 0V | |
Good
- Go to "COMPONENT INSPECTION " procedure.
No Good
- Repair open or short in circuit and then go to "VERIFICATION OF REPAIR " procedure.