| DTC Strategy |
Case1 |
- Maximum humidity plausibility check
|
- Poor connector connection
- Faulty humidity sensor (MAFS) circuit
- Faulty humidity sensor (MAFS)
|
| Case2 |
|
| Enable Conditions |
Case1 |
- If the coolant temperature is below 70°C
- When the temperature difference between the humidity sensor internal temperature value and the ambient air temperature sensor is 6°C or higher
- General conditions for monitoring the reliability of the humidity sensor
- HFM chip heating not applied
- When there is no humidity sensor device error
- When there is no humidity sensor protocol error
- When the detection value of the ambient air temperature sensor is -10°C or less than 50°C
- When the coolant temperature value is -10°C or less than 60°C at engine start-up
- The difference between the coolant temperature value and the ambient air temperature sensor at engine start-up is less than 10°C
- The accumulation of crankshaft rotations is more than 100 times
|
| Case2 |
- General conditions for monitoring the reliability of the humidity sensor
- HFM chip heating not applied
- When there is no humidity sensor device error
- When there is no humidity sensor protocol error
- When the detection value of the ambient air temperature sensor is -10°C or less than 50°C
- When the coolant temperature value is -10°C or less than 60°C at engine start-up
- The difference between the coolant temperature value and the ambient air temperature sensor at engine start-up is less than 10°C
- The accumulation of crankshaft rotations is more than 100 times
|
| Threshold Value |
Case1 |
- If there is an abnormality in the maximum relative humidity value
|
| Case2 |
- If the difference between the maximum relative humidity and the minimum relative humidity is less than 5%
- The difference between the maximum HFM humidity temperature and the minimum HFM humidity temperature is 10°C or higher
|
| Diagnostic Time |
|
| MIL ON Condition |
|